  • KPM75 Power quality analyzer

    KPM75 is a new generation high-end power quality analyzer that follow international power quality standards and monitor all power quality parameters such as flicker, short interruptions in recorded voltage, and harmonic up to 63 measurements, etc.
    Overview Function Specifications Wiring Diagram Download

    KPM75 is a new generation high-end power quality analyzer that follow international power quality standards and monitor all power quality parameters such as flicker, short interruptions in recorded voltage, and harmonic up to 63 measurements with power data Statistics, IO signal control alarm, communication and other functions. Large graphic LCD display, pluggable function module design, widely used in key power applications, it is the ideal choice to monitor the distribution operation efficiency.


    Application occasion

    • Measure, monitor and control power distribution system parameters
    • Collect energy consumption data that cost center analysis needs
    • Power quality analysis(Harmonic, voltage interruption, flicker and so on)
    • Signal control alarm 





    Function features

    • Measure the real effective value of all-parameter
    • 63th harmonic measurement and analysis
    • Measure voltage imbalance rate, voltage deviation, frequency deviation and other power quality parameters
    • Measurement and recording voltage fluctuations and flicker, inter-harmonics and other power quality parameters
    • Short-term interruption of voltage, surge, sudden drop and other power quality events recorded
    • Demand statistics function, record the current value and maximum value
    • 0.2S four quadrant power statistics
    • Can set 4 kinds rates 8 time period multi-rate power statistics
    • RS485 communication interface, Modbus-RTU protocol, Optional Profibus-DP
    • 1 road passive optical coupler collector active pulse output
    • Can be extended 4-way passive switch value input
    • Instrument working hours, load time statistics
    • 160 * 160 graphic LCD screen, rich in content, intuitive and clear
    • Pluggable design, appearence design patents, replacement and maintenance easy




    Working power source Operating Voltage AC 85-265V/DC 80-300V
    Rated power consumption < 3VA
    Input voltage Rated voltage 57.7/100V,220/380V,380/660V
    Overvoltage capability 1.2 times rated voltage allowed, continuous work;
    2 times the rated voltage allowed 1 second
    Rated power consumption <0.5VA(per phase)
    Measurement range 5A:0-6A;  1A:0-1.2A
    Input current Rated current Default 5A, input range 1-6A;
    optional 1A, input range 1-1.2A
    Overload capacity 1.2 times rated current allowed, continuous work;
    20 times the rated current allowed 1 second
    Rated power consumption <0.4VA(per phase)
    Accuracy range 5A:>5mA;  
    1A:>0.8mA
    Measurement accuracy Voltage ±0.2%(0.01V)
    Current ±0.2%(0.01A)
    Active power ±0.2%(0.01W)
    Reactive power ±2.0%(0.01var)
    Power factor ±1.0%(0.001)
    Frequency ±0.002Hz
    Active energy ±0.2%(0.1kwh)
    Reactive energy ±2.0%(0.1kvarh)
    Measurement display Basic parameter Voltage / current, active power, reactive power, apparent power, frequency, active energy
    Power quality 2-63 harmonic distortion rate; total harmonic distortion rate; crest factor; current K factor; voltage / current imbalance rate, flicker, voltage surge, dips, short interruptions
    Demand statistics Power demand maximum, minimum and current value
    Multi-rate 8 time periods, 4 kinds of rates
    historical data Record monthly average power factor and power data for the last three months
    Communication
     
    communication port RS485,Photoelectric isolation interface
    Communication protocol Modbus-RTU, 1200-38400BPS
    Probibus-DP,9600-12Mbps
    Input,output
     
     
    Switch value input 4-way passive main line contact DI input, internal supply DC24V power supply
    Relay output 4-Way DO output, contact capacity 250VAC / 5A, 30VDC / 5A
    Pulse output 1-way passive optocoupler collector active pulse output
    Product features Display 160 * 160 large dot-matrix LCD graphics display
    Extensions function Pluggable expansion design
    Degree of protection IP54
    Dimensions 96*96*88
    Working environment Operating temperature -25℃ ~ +70℃
    Storage temperature -30℃ ~ +75℃
    Relative humidity 5% ~ 95% No condensation
    Altitude Not more than 4000m
    Safety Withstand voltage AC2kV/min~1mA input-output-source 
    Insulation >50MΩ 
    Electromagnetic Compatibility Surge(impact) immunity IEC61000-4-5,Level4
    Electrical fast burst immunity IEC61000-4-4,Level4
    Electrostatic discharge immunity IEC61000-4-3,Level4
    Power frequency magnetic immunity IEC61000-4-8,Level4




    Explanation
    1. The wiring diagram is suitable for high voltage three-phase three-wire system, low voltage three-phase four-wire system, regard to other system wiring. 2. Please refer to KPM75 instruction manual.
    3. Analog output AO- and switch input common COM share one terminal.
    4. Terminal that without function description is invalid.
    5. The function of dotted lines is optional.
    6. The final interpretation belongs to Compere.

    主站蜘蛛池模板: 99sescom色综合| 色爱区综合激情五月综合色| 婷婷五月综合缴情在线视频| 国产精品综合在线| 色综合天天综合网国产国产人| 97se色综合一区二区二区| 狠狠色狠狠色综合网| 久久婷婷午色综合夜啪| 伊人丁香狠狠色综合久久| 伊人情人综合成人久久网小说| 99v久久综合狠狠综合久久| 亚洲综合激情另类专区| 国产成人无码综合亚洲日韩 | 亚洲色婷婷综合久久| 99久久国产综合精品1尤物| 国产综合色香蕉精品五月婷| 国产91久久综合| 五月天综合色激情| 国产色综合天天综合网| 亚洲综合色丁香婷婷六月图片| 亚洲国产精品成人AV无码久久综合影院 | 国产成人AV综合久久| 亚洲精品第一国产综合野| 亚洲av综合日韩| 国产精品国产色综合色| 亚洲色图综合网站| 久久久综合九色合综国产精品| 好吊色青青青国产综合在线观看| 狠狠色丁香久久婷婷综合五月| 欧洲亚洲综合一区二区三区| 亚洲另类激情综合偷自拍| 久久综合中文字幕| 国产激情综合在线观看| 精品国产国产综合精品| 精品福利一区二区三区精品国产第一国产综合精品 | 丁香婷婷色五月激情综合深爱| 色噜噜狠狠色综合欧洲selulu| 久久婷婷五月综合97色| 久久天天躁狠狠躁夜夜躁综合| 狠狠狠色丁香婷婷综合久久五月| 久久综合视频网站|